GPeR Gigabit Passive Ethernet Repeater
GPeR Gigabit Passive Ethernet Repeater
| Prezzo: | €42,00 Iva esclusa (22%) |
|---|---|
| Spese di trasporto: | A partire da € 9,90 Iva esclusa (22%)Maggiori dettagli |
| Marca: | MIKTROTIK |
| Codice Interno: | 10004802 |
| Cod. Vendita: | GPeR |
| P/N Produttore: | GPeR |
| MOQ: | 1 |
| Condizione:: | Standard - Nuovo |
| Lead Time Fabbrica - se 0 PZ: | 1 settimana |
| RICHIEDI PREVENTIVO: | Per quantitativi maggiori, progetti, ordini continuativi |
| Unità di misura: | PZ |
| Disponibilità: | Disponibile |
| Quantità: |
Descrizione
The GPeR unit allows to extend Ethernet cable by additional hop (< 100 - 150 m to regular network devices, and up to 210 m to another GPeR unit) up to 1,500 m.
Handy for highrise buildings, multi-apartment buildings, with many floors and sections, where very long Ethernet cables might be a problem.
Maximum allowed length of CAT6 Ethernet cable between GPeR and power source/router is up to 100 m (depending on cable quality, high quality - up to 150 m).
Maximum allowed distance of CAT6 Ethernet cable between two GPeR devices is up to 210 m (depending on cable quality).
In case if the destination device does not support PoE-in powering, the PoE Passthrough can be disabled by manually removing all jumpers.
Handy for highrise buildings, multi-apartment buildings, with many floors and sections, where very long Ethernet cables might be a problem.
Maximum allowed length of CAT6 Ethernet cable between GPeR and power source/router is up to 100 m (depending on cable quality, high quality - up to 150 m).
Maximum allowed distance of CAT6 Ethernet cable between two GPeR devices is up to 210 m (depending on cable quality).
In case if the destination device does not support PoE-in powering, the PoE Passthrough can be disabled by manually removing all jumpers.